Home/
"ASANTE" HOME-USE OXYGEN CONCENTRATOR
HK$6,600.00
Seller Information
ONE STOP MEDICAL LIMITED
More about this shopFree Shipping upon $*500 *Note: The amount after deducting product discounts, coupons and shipping charges.
Delivery Fee $60
Delivery Fee 5-7 working days
Home Delivery
Product code
825852
About this product
Description
WIDE APPLICABILITY: SUITABLE FOR PATIENTS WITH RESPIRATORY DISEASES, OXYGEN SUPPLEMENTATION FOR THE ELDERLY, PRENATAL OXYGEN SUPPLEMENTATION FOR PREGNANT WOMEN, AND HIGH-ALTITUDE OXYGEN SUPPLEMENTATION.
HIGH-CONCENTRATION OXYGEN OUTPUT: OXYGEN CONCENTRATION REACHES 93% ±3% (V/V), STABILIZING APPROXIMATELY 30 MINUTES AFTER STARTUP.
ADJUSTABLE FLOW RANGE: 0.6–5L/MIN WITH AN ACCURACY OF ±10% OR ±200ML/MIN; TRIGGERS A LOW-FLOW ALARM WHEN THE FLOW DROPS BELOW 0.6L/MIN.
NEBULIZATION FUNCTION: AIRFLOW ≥3L/MIN, PRESSURE ≤240KPA, NEBULIZATION RATE ≥0.2ML/MIN, RESIDUAL LIQUID ≤2ML, CONTINUOUS OPERATION >4 HOURS, AND MEDIAN MASS AERODYNAMIC DIAMETER OF NEBULIZED PARTICLES AT 4.5ΜM (±25%).
MULTIPLE ALARMS AND PROTECTIONS: INCLUDES COMPRESSOR ABNORMALITY, HIGH-TEMPERATURE PROTECTION, CYCLE PRESSURE FAULT, LOW OXYGEN CONCENTRATION, ETC., ENSURING USER SAFETY.
ACCESSORY SUPPORT: NASAL OXYGEN CANNULA REQUIRED. HUMIDIFIER BOTTLE AND NEBULIZER COMPONENTS SUCH AS NEBULIZER CUPS, MASKS, MOUTHPIECES, AND CONNECTING TUBES ARE OPTIONAL.
ELECTROMAGNETIC COMPATIBILITY: COMPLIES WITH YY 9706.102-2021 STANDARDS, FEATURING RESISTANCE TO RADIO-FREQUENCY CONDUCTION AND RADIATION INTERFERENCE.
DIMENSIONS (L X W X H): 42CM X 28CM X 55CM
PRODUCT SPECIFICATIONS:
RATED VOLTAGE AND FREQUENCY: AC220V, 50HZ
OPERATING MODE: CONTINUOUS OPERATION
RATED INPUT POWER: 400VA
NOISE LEVEL: ≤60DB(A) AT 5L/MIN; MAXIMUM ≤67DB
ALARM VOLUME: ≥50DB(A)
OPERATING ALTITUDE: ≤1828M (FLOW RATE AND CONCENTRATION BECOME ABNORMAL IF EXCEEDED)
OXYGEN CONCENTRATION: 93% ±3% (V/V) (30 MINUTES AFTER STARTUP)
FLOW RANGE: 0.6–5L/MIN (NOT RECOMMENDED BELOW 1L/MIN; MAXIMUM RECOMMENDED FLOW IS 5L/MIN)
FLOW ACCURACY: ±10% OR ±200ML/MIN (UNDER 0KPA AND 7KPA BACKPRESSURE)
MAXIMUM OUTPUT PRESSURE: ≤70KPA
SYSTEM PRESSURE PROTECTION: 241 ±24.1KPA
CIRCUIT BREAKER: 5A
NEBULIZATION PARAMETERS: AIRFLOW ≥3L/MIN; PRESSURE ≤240KPA; NEBULIZATION RATE ≥0.2ML/MIN; RESIDUAL LIQUID ≤2ML; CONTINUOUS OPERATION >4H; PARTICLE MEDIAN DIAMETER 4.5ΜM (±25%)
IP RATING: IP21 (PARTICLE PROTECTION LEVEL 2, WATERPROOF LEVEL 1)
DIMENSIONS (L X W X H): 42CM X 28CM X 55CM
OPERATING ENVIRONMENT: TEMPERATURE +5 TO +40℃; RELATIVE HUMIDITY ≤80%; ATMOSPHERIC PRESSURE 86–106KPA
EXHAUST / OXYGEN OUTPUT TEMPERATURE: EXHAUST ≤75℃; OXYGEN OUTPUT ≤45℃
COMPONENTS: FILTRATION SYSTEM, COMPRESSOR, FLOWMETER, MOLECULAR SIEVE TANK, CIRCUIT CONTROL SYSTEM, NOISE REDUCTION SYSTEM, EMBEDDED SOFTWARE (ZY002), OUTER CASING, REMOTE CONTROL (OPTIONAL)
ACCESSORIES: NASAL OXYGEN CANNULA (2.5M, CRUSH-RESISTANT), HUMIDIFIER BOTTLE, NEBULIZER KIT (OPTIONAL)
PLACEMENT REQUIREMENTS: DISTANCE FROM WALLS/FURNITURE ≥7.5CM; AVOID DUST/CONFINED SPACES
HIGH-CONCENTRATION OXYGEN OUTPUT: OXYGEN CONCENTRATION REACHES 93% ±3% (V/V), STABILIZING APPROXIMATELY 30 MINUTES AFTER STARTUP.
ADJUSTABLE FLOW RANGE: 0.6–5L/MIN WITH AN ACCURACY OF ±10% OR ±200ML/MIN; TRIGGERS A LOW-FLOW ALARM WHEN THE FLOW DROPS BELOW 0.6L/MIN.
NEBULIZATION FUNCTION: AIRFLOW ≥3L/MIN, PRESSURE ≤240KPA, NEBULIZATION RATE ≥0.2ML/MIN, RESIDUAL LIQUID ≤2ML, CONTINUOUS OPERATION >4 HOURS, AND MEDIAN MASS AERODYNAMIC DIAMETER OF NEBULIZED PARTICLES AT 4.5ΜM (±25%).
MULTIPLE ALARMS AND PROTECTIONS: INCLUDES COMPRESSOR ABNORMALITY, HIGH-TEMPERATURE PROTECTION, CYCLE PRESSURE FAULT, LOW OXYGEN CONCENTRATION, ETC., ENSURING USER SAFETY.
ACCESSORY SUPPORT: NASAL OXYGEN CANNULA REQUIRED. HUMIDIFIER BOTTLE AND NEBULIZER COMPONENTS SUCH AS NEBULIZER CUPS, MASKS, MOUTHPIECES, AND CONNECTING TUBES ARE OPTIONAL.
ELECTROMAGNETIC COMPATIBILITY: COMPLIES WITH YY 9706.102-2021 STANDARDS, FEATURING RESISTANCE TO RADIO-FREQUENCY CONDUCTION AND RADIATION INTERFERENCE.
DIMENSIONS (L X W X H): 42CM X 28CM X 55CM
PRODUCT SPECIFICATIONS:
RATED VOLTAGE AND FREQUENCY: AC220V, 50HZ
OPERATING MODE: CONTINUOUS OPERATION
RATED INPUT POWER: 400VA
NOISE LEVEL: ≤60DB(A) AT 5L/MIN; MAXIMUM ≤67DB
ALARM VOLUME: ≥50DB(A)
OPERATING ALTITUDE: ≤1828M (FLOW RATE AND CONCENTRATION BECOME ABNORMAL IF EXCEEDED)
OXYGEN CONCENTRATION: 93% ±3% (V/V) (30 MINUTES AFTER STARTUP)
FLOW RANGE: 0.6–5L/MIN (NOT RECOMMENDED BELOW 1L/MIN; MAXIMUM RECOMMENDED FLOW IS 5L/MIN)
FLOW ACCURACY: ±10% OR ±200ML/MIN (UNDER 0KPA AND 7KPA BACKPRESSURE)
MAXIMUM OUTPUT PRESSURE: ≤70KPA
SYSTEM PRESSURE PROTECTION: 241 ±24.1KPA
CIRCUIT BREAKER: 5A
NEBULIZATION PARAMETERS: AIRFLOW ≥3L/MIN; PRESSURE ≤240KPA; NEBULIZATION RATE ≥0.2ML/MIN; RESIDUAL LIQUID ≤2ML; CONTINUOUS OPERATION >4H; PARTICLE MEDIAN DIAMETER 4.5ΜM (±25%)
IP RATING: IP21 (PARTICLE PROTECTION LEVEL 2, WATERPROOF LEVEL 1)
DIMENSIONS (L X W X H): 42CM X 28CM X 55CM
OPERATING ENVIRONMENT: TEMPERATURE +5 TO +40℃; RELATIVE HUMIDITY ≤80%; ATMOSPHERIC PRESSURE 86–106KPA
EXHAUST / OXYGEN OUTPUT TEMPERATURE: EXHAUST ≤75℃; OXYGEN OUTPUT ≤45℃
COMPONENTS: FILTRATION SYSTEM, COMPRESSOR, FLOWMETER, MOLECULAR SIEVE TANK, CIRCUIT CONTROL SYSTEM, NOISE REDUCTION SYSTEM, EMBEDDED SOFTWARE (ZY002), OUTER CASING, REMOTE CONTROL (OPTIONAL)
ACCESSORIES: NASAL OXYGEN CANNULA (2.5M, CRUSH-RESISTANT), HUMIDIFIER BOTTLE, NEBULIZER KIT (OPTIONAL)
PLACEMENT REQUIREMENTS: DISTANCE FROM WALLS/FURNITURE ≥7.5CM; AVOID DUST/CONFINED SPACES